Older boiler diagnosis
We identify the model, check the manual and assess what can be repaired.
Ask about your boilerWe identify the model, check the manual and look into parts before recommending the next step.
The phone is answered 24 hours a day, by a person and not a machine.
A fault code narrows down where to look. It does not say whether a boiler is worth repairing, and it does not say which part has failed. Below is what the manufacturer manual says, with the page it says it on, and our guide to the likely remedy.
| Model and fault | The issue | Manual source | Likely remedy |
|---|---|---|---|
Baxi Bermuda BBU 15 HEE133
|
Interruption of the gas supply, failed ignition, or no flame detected. On this model a three digit code is shown split, so E133 appears as "E1" alternating with "33". |
Installation & Servicing Instructions, 2014, p. 36 [M] | Check that other gas appliances work and the meter is on and in credit. If gas is on, the ignition or the gas valve is the likely fix, and an engineer does that. |
Baxi Bermuda BBU 15 HEE158
|
Condensate discharge system fault. | Installation & Servicing Instructions, 2014, p. 36 [M] | Check the condensate pipe first: a frozen or blocked one is common. Thaw it with warm water, never boiling, if you can reach it safely. If the code stays, an engineer checks the drain. |
Baxi Bermuda BBU 15 HEE125
|
Circulation fault in the primary circuit. The manual gives the trigger as the boiler exceeding the selected temperature by 25°C twice within two hours of the burner lighting. | Installation & Servicing Instructions, 2014, p. 36 [M] | Check there is enough water in the system and that the radiator valves are open, then bleed the radiators. If the code stays, an engineer checks the pump. |
Baxi Bermuda BBU 15 HEE110
|
The primary water has overheated, or there is excess condensate in the sump. The manual limits the boiler to four resets in any five hour period. |
Installation & Servicing Instructions, 2014, p. 36 [M] | Let it cool and check the radiators are open and the condensate can drain. The manual allows a reset, held for five seconds: reset it once. If it comes back, call an engineer. |
Potterton Promax Store 24E110
|
Safety thermostat operated: the primary water has overheated. | Installation and Service Manual, p. 47 [M] | Check the radiator valves are open and the system has enough water. Do not keep resetting it: have the cause checked. |
Potterton Promax Store 24E119
|
Water pressure switch not operated: the primary water pressure is below 0.5 bar. | Installation and Service Manual, p. 47 [M] | Top the pressure up with the filling loop until the gauge reads normal. If it keeps dropping, there is a leak to find and repair. |
Potterton Promax Store 24E125
|
Pump fault or a primary circulation problem. The manual says the pump is probably not working. | Installation and Service Manual, p. 47 [M] | Check the radiator valves are open. If the code stays, the pump is the likely fault, and an engineer tests it. |
Potterton Promax Store 24E130
|
Flue sensor operated: the flue system has overheated. | Installation and Service Manual, p. 47 [M] | Do not reset it. Turn the boiler off; an engineer checks the flue and the sensor before it is used again. |
Potterton Promax Store 24E133
|
Interruption of the gas supply, failed ignition, or no flame detected. | Installation and Service Manual, p. 47 [M] | Check other gas appliances and the meter. In cold weather, check the outside condensate pipe has not frozen. If gas is on and it still will not light, the ignition or the gas valve needs an engineer. |
Potterton Promax Store 24E160
|
Fan or fan wiring fault. | Installation and Service Manual, p. 47 [M] | Do not keep resetting it. The fan clears the combustion gases, so this is safety critical: an engineer checks the fan and its wiring. |
Potterton Promax Store 24E193
|
Pre-circulation fault. | Installation and Service Manual, p. 47 [M] | This one needs an engineer, to find the cause of the circulation fault. |
Worcester Greenstar CDi ClassicA1
|
The pump has run dry. | Engineer’s Service Booklet (6 720 830 033), 2014, p. 11 [M] | If the pressure gauge has dropped, the system needs re-pressurising and the leak finding. If the code stays, the pump may be stuck or worn, and an engineer frees or replaces it. |
Worcester Greenstar CDi ClassicA5
|
The tank (heat bank) temperature sensor is faulty. The boiler still answers heating demands. | Engineer’s Service Booklet (6 720 830 033), 2014, p. 12 [M] | An engineer checks the tank sensor and its connection, and replaces it if it has failed. |
Worcester Greenstar CDi ClassicA6
|
The external underfloor heating thermostat is faulty. The boiler will not answer demands. | Engineer’s Service Booklet (6 720 830 033), 2014, p. 12 [M] | An engineer checks the thermostat and its wiring. |
Worcester Greenstar CDi ClassicA7
|
The hot water temperature sensor is faulty. Hot water may still come, less accurately controlled. | Engineer’s Service Booklet (6 720 830 033), 2014, p. 13 [M] | An engineer checks the hot water sensor, its wiring and the control board. |
Worcester Greenstar CDi ClassicA8
|
Communication to the programmer has been interrupted. | Engineer’s Service Booklet (6 720 830 033), 2014, p. 14 [M] | An engineer checks the programmer, its cable and the control board. |
Worcester Greenstar CDi Classicb1
|
The code plug is not detected. | Engineer’s Service Booklet (6 720 830 033), 2014, p. 15 [M] | An engineer checks the code plug is the right one for this boiler and is fitted properly. |
Worcester Greenstar CDi ClassicC6
|
The fan speed is too low. | Engineer’s Service Booklet (6 720 830 033), 2014, p. 15 [M] | Worcester tells owners not to try to fix this one. An engineer checks the fan, its lead and the supply voltage. |
Worcester Greenstar CDi ClassicCC
|
The outside temperature sensor has an open or short circuit. | Engineer’s Service Booklet (6 720 830 033), 2014, p. 16 [M] | An engineer checks the outside sensor and its wiring, and replaces it if it has failed. |
Worcester Greenstar CDi ClassicE2
|
The flow temperature sensor is faulty. | Engineer’s Service Booklet (6 720 830 033), 2014, p. 16 [M] | An engineer checks the flow sensor, its connector and the control board. |
Worcester Greenstar CDi ClassicE9
|
The safety temperature circuit has tripped. | Engineer’s Service Booklet (6 720 830 033), 2014, p. 17 [M] | Worcester tells owners not to try to fix this one. An engineer checks the water pressure, the pump and the safety limiters. |
Worcester Greenstar CDi ClassicEA
|
The flame is not detected while the boiler is running. | Engineer’s Service Booklet (6 720 830 033), 2014, p. 19 [M] | If it is safe to do so, check the gas is on, the condensate pipe has not frozen and the flue outlet is not blocked. If it still will not light, an engineer checks the electrodes, the gas valve and the flue. |
Worcester Greenstar CDi ClassicF0
|
Internal failure. | Engineer’s Service Booklet (6 720 830 033), 2014, p. 21 [M] | Hold the reset button for three seconds, once. If it comes back, an engineer checks the control board. |
Worcester Greenstar CDi ClassicF7
|
A flame is still detected although the boiler has switched off. | Engineer’s Service Booklet (6 720 830 033), 2014, p. 22 [M] | Turn the boiler off and leave it off. Worcester tells owners not to try to fix this one: an engineer checks the electrodes and the flue. |
Worcester Greenstar CDi ClassicFA
|
A flame is detected after the boiler has switched off. | Engineer’s Service Booklet (6 720 830 033), 2014, p. 23 [M] | Turn the boiler off and leave it off. Worcester tells owners not to try to fix this one: an engineer checks the condensate trap, the electrodes, the flue and the gas valve. |
Worcester Greenstar CDi ClassicFd
|
The reset button was pressed by mistake. | Engineer’s Service Booklet (6 720 830 033), 2014, p. 24 [M] | Hold the reset button for three seconds and it should restart. If the code stays, an engineer checks the control board. |
Worcester Greenstar CDi ClassicSE
|
The burner has run for 2324 hours since the boiler was last checked. It is a service reminder, not a fault. | Engineer’s Service Booklet (6 720 830 033), 2014, p. 24 [M] | Book the annual service. The engineer resets the code afterwards. |
Vaillant ecoTEC plusF.20
|
The flow or return temperature got too high, and the safety cut-out stopped the boiler. | Installation and maintenance instructions, VU, VUW ..6/5-5 (0020244997_02), 2018, p. 46 [M] | Check the pressure gauge, and top the water up if it is low. If it repeats, an engineer checks the flow sensor and the pump. |
Vaillant ecoTEC plusF.22
|
Low water pressure: there is no or not enough water in the boiler. | Installation and maintenance instructions, VU, VUW ..6/5-5 (0020244997_02), 2018, p. 46 [M] | Top up the water pressure. If it drops again, an engineer looks for the leak, or checks the pressure sensor and the pump. |
Vaillant ecoTEC plusF.23
|
The temperature spread is too great: the water is not circulating enough. | Installation and maintenance instructions, VU, VUW ..6/5-5 (0020244997_02), 2018, p. 46 [M] | Check the pressure gauge, and top the water up if it is low. If it stays, an engineer checks the pump and the water pressure sensor. |
Vaillant ecoTEC plusF.24
|
The water temperature rose too fast. | Installation and maintenance instructions, VU, VUW ..6/5-5 (0020244997_02), 2018, p. 46 [M] | Low water or air in the system can cause it: check the pressure gauge, and top the water up if it is low. If it stays, an engineer checks the pump. |
Vaillant ecoTEC plusF.25
|
The flue gas temperature is too high. | Installation and maintenance instructions, VU, VUW ..6/5-5 (0020244997_02), 2018, p. 46 [M] | Turn the boiler off and call an engineer: the flue route or a safety cut-out needs checking. |
Vaillant ecoTEC plusF.26
|
The gas valve is not working: its motor is faulty or not connected. | Installation and maintenance instructions, VU, VUW ..6/5-5 (0020244997_02), 2018, p. 46 [M] | An engineer checks the gas valve motor and its wiring. |
Vaillant ecoTEC plusF.27
|
Flame simulation: the monitoring electrode reports an incorrect flame. | Installation and maintenance instructions, VU, VUW ..6/5-5 (0020244997_02), 2018, p. 46 [M] | Do not keep resetting it. An engineer checks the monitoring electrode, the gas valve and the control board. |
Vaillant ecoTEC plusF.28
|
Ignition failed at start-up. | Installation and maintenance instructions, VU, VUW ..6/5-5 (0020244997_02), 2018, p. 46 [M] | Check the gas stopcock is open, other gas appliances work and, in cold weather, the condensate pipe has not frozen. If it still will not light, the ignition parts or the gas valve need an engineer. |
Vaillant ecoTEC plusF.29
|
Ignition failed while running: the gas was interrupted and it would not relight. | Installation and maintenance instructions, VU, VUW ..6/5-5 (0020244997_02), 2018, p. 46 [M] | Check the gas is on and the condensate pipe is not blocked. If the code stays, an engineer checks the flue, the earthing and the wiring. |
Vaillant ecoTEC plusF.32
|
Fan fault: the fan is faulty or not connected. | Installation and maintenance instructions, VU, VUW ..6/5-5 (0020244997_02), 2018, p. 46 [M] | Do not keep resetting it. An engineer checks the fan, its wiring and the flue route. |
Vaillant ecoTEC plusF.54
|
There was no, or too little, gas pressure at the boiler when it started. | Installation and maintenance instructions, VU, VUW ..6/5-5 (0020244997_02), 2018, p. 46 [M] | Check the gas stopcock is open and other gas appliances work. If gas is on, an engineer checks the gas valve and its wiring. |
Vaillant ecoTEC plusF.61
|
The gas valve cannot be operated. | Installation and maintenance instructions, VU, VUW ..6/5-5 (0020244997_02), 2018, p. 46 [M] | An engineer checks the gas valve, its wiring and the control board. |
Vaillant ecoTEC plusF.62
|
The gas valve closes late after the flame goes out. | Installation and maintenance instructions, VU, VUW ..6/5-5 (0020244997_02), 2018, p. 46 [M] | Turn the boiler off and call an engineer, who checks the gas valve and the burner surface. |
Vaillant ecoTEC plusF.68
|
The flame signal is unstable. | Installation and maintenance instructions, VU, VUW ..6/5-5 (0020244997_02), 2018, p. 47 [M] | An engineer checks the air ratio, the gas pressure, the condensate route and the flame sensor. |
Vaillant ecoTEC plusF.73
|
The water pressure sensor reads too low a pressure. | Installation and maintenance instructions, VU, VUW ..6/5-5 (0020244997_02), 2018, p. 47 [M] | Check the pressure gauge and top up if it is low. If the gauge is right, an engineer checks the pressure sensor and its wiring. |
Vaillant ecoTEC plusF.74
|
The water pressure is too high. | Installation and maintenance instructions, VU, VUW ..6/5-5 (0020244997_02), 2018, p. 47 [M] | Check the pressure gauge. If it reads too high, some water needs letting out of the system. If the code stays, an engineer checks the pressure sensor. |
Vaillant ecoTEC plusF.75
|
Pump or water shortage: not enough of a pressure rise was detected when the pump started. | Installation and maintenance instructions, VU, VUW ..6/5-5 (0020244997_02), 2018, p. 47 [M] | Check the pressure gauge, and top the water up if it is low. If it stays, an engineer checks the pump, the pressure sensor and the expansion vessel. |
Ideal Logic CombiL1
|
Flow temperature overheat lockout. The display shows L and 1 one after the other. |
Installation and Servicing, Logic Combi 24, 30, 35, p. 53 [M] | Fill the system to the right pressure, bleed the radiators and open the radiator valves, then reset it. If it locks out again, an engineer checks the pump. |
Ideal Logic CombiL2
|
Ignition lockout. The display shows L and 2 one after the other. |
Installation and Servicing, Logic Combi 24, 30, 35, p. 53 [M] | Check other gas appliances work and the gas is on at the meter, and that the condensate pipe is not blocked or frozen, then reset it. If it still will not light, the ignition parts, the gas valve or the flue need an engineer. |
Ideal Logic CombiL6
|
False flame lockout. The display shows L and 6 one after the other. |
Installation and Servicing, Logic Combi 24, 30, 35, p. 54 [M] | Ideal tells owners to contact an installer for this one. An engineer checks the flame sensor and its wiring. |
Ideal Logic CombiF1
|
Low water pressure. The display shows F and 1 one after the other. |
Installation and Servicing, Logic Combi 24, 30, 35, p. 54 [M] | Top up the pressure: the gauge should read between 1 and 1.5 bar, with all the valves open. If it keeps dropping, an engineer looks for the leak or checks the pressure sensor. |
Ideal Logic CombiF2
|
Flame loss. The display shows F and 2 one after the other. |
Installation and Servicing, Logic Combi 24, 30, 35, p. 55 [M] | Check other gas appliances work and the gas is on at the meter. If it keeps happening, an engineer checks the flame sensor, the condensate pipe and the flue. |
Ideal Logic CombiF3
|
Fan fault. The display shows F and 3 one after the other. |
Installation and Servicing, Logic Combi 24, 30, 35, p. 55 [M] | Do not keep resetting it. An engineer checks the fan and its wiring. |
Ideal Logic CombiF4
|
Thermistor fault: the flow thermistor, in the top of the heat exchanger. The display shows F and 4 one after the other. |
Installation and Servicing, Logic Combi 24, 30, 35, p. 56 [M] | An engineer checks the flow sensor and its wiring. |
Ideal Logic CombiF5
|
Return thermistor fault: on the central heating return pipe. The display shows F and 5 one after the other. |
Installation and Servicing, Logic Combi 24, 30, 35, p. 56 [M] | An engineer checks the return sensor and its wiring. |
Ideal Logic CombiF6
|
Outside sensor fault. The display shows F and 6 one after the other. |
Installation and Servicing, Logic Combi 24, 30, 35, p. 57 [M] | An engineer checks the outside sensor and its wiring. |
Ideal Logic Combic2
|
BCC fault (boiler chip card). The display shows c and 2 one after the other. |
Installation and Servicing, Logic Combi 24, 30, 35, p. 57 [M] | An engineer checks the boiler chip card is fitted and is the right one for this boiler. |
The issue comes from the manufacturer manual. The likely remedy is a guide: it depends on inspection and on parts.
A code on its own cannot decide whether a boiler should be replaced.
A discontinued boiler deserves a proper assessment.
We identify the model, check the manual and assess what can be repaired.
Ask about your boilerWe look at parts, condition and how long the model can be supported before recommending the next step.
Ask about your boilerWe find the fault, explain it, and fix it where the part can be had.
Ask about your boilerAn annual check keeps small faults from turning into breakdowns.
Ask about your boilerRepairs to unvented hot water cylinders and their controls.
Ask about your boilerA model number or a photograph is a useful first step.
We ask a few questions and note the model if you have it.
We look up the manual and find out what can be had.
We explain the options and only go ahead with your approval.
A price for a boiler nobody has seen is a guess. We look at yours first.
Tell us where you are and what the boiler is doing. We will call you back.
Often, yes. We identify the model from the data badge and check what stockists hold before anything is agreed. Where a part is no longer held, we will tell you.
Yes. There is no law against an older boiler. It has to be safe, and a Gas Safe registered engineer has to say so.
Many firms only work on models they fit themselves. We work on older and discontinued ranges, which is the whole point of this business.
A price for a boiler nobody has seen is a guess. We look at yours, then give you a clear quote before any work begins.